NHX
Nurse Center System
NH-1SA-AC
NH-2SA-AC
Patient Stations
Single and Dual Patient Stations for All Call,
and when sharing a common Corridor Lamp
- INSTRUCTIONS -
Some applications for Nurse Call systems require All Call. By including the NH-50AC adaptor and the "AC" model
patient stations, a station button on the master can be used to call all of the patient stations simultaneously. An
additional wire is required to each patient station. In addition, if there is more than one patient station sharing a
corridor lamp, this model patient station will allow that configuration to be used.
NOTE: An NHX system installed with an NH-1SA-AC or NH-2SA-AC included does not carry the UL 1069 listing.
Two Patient Stations in one room sharing a bathroom and corridor lamp
WIRING DIAGRAM:
NH-1SA-AC
NH-2SA-AC
APPLICATION #1:
NHX-80X
CN1:
Brn
Red
Org
Yel
CN1:
Brn
Red
Org
Yel
All Call feature added, where an announcement can
be made from the master station to all patient
stations simultaneously.
APPLICATION #2:
2 patient stations in a room with a common
bathroom and one corridor lamp outside the room.
11
12
13
14
15
16
Trunkage Line
Connection
Terminals
Grn
Blu
Grn
Blu
To NH-50AC
Blk
Blk
21
22
23
24
25
26
~
51
52
53
54
55
56
NHR-4A
CN2:
Brn
Red
Org
Yel
Grn
Blu
Vio
CN2:
Brn
Red
Org
Yel
Grn
Blu
Vio
Corridor Lamp
(Shared by both patient stations)
Brn
Red
Org
NHR-7A
Bathroom Pullcord
(Wired to one station only)
Yel
Grn
* Bath call will annunciate on
one position at the master
station, according to which
patient station it is wired to.
Blu
PS-2420UL
A+
A-
+
-
NOTES:
1. All Call requires one of the station buttons to be used for All Call.
Therefore, the standard system can have up to 49 stations, and the expanded
system can have up to 79 stations.
B+
B-
+
-
2. Only wiring concerning the NH-1SA-AC and NH-2SA-AC is shown here. For
complete installation and wiring information, please see the NHX Installation
instructions.
PS-2420UL
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
TOLL FREE FAX LINE:
(800) 832-3765
E-MAIL: tech-serv@aiphone.com
NH-1/2SA-AC Instr.
0103js
FAX (425) 455-0071
|
MTD 240 650 000 User Manual
Mr Coffee Coffeemaker 7988 33 User Manual
Motorola I475W User Manual
Kenwood KDC X715 User Manual
Jensen CD 472 User Manual
Fujitsu FOR BOARD TO CABLE CONNECTION 240 User Manual
FieldServer Omron FINS FS 8704 16 User Manual
Clarion DRB465D User Manual
Braun KF 185 User Manual
Black & Decker DE43 User Manual